Specification
Specifications apply over entire operating temperature range.
Typical values are specified at Vcc = 5.0Vdc and 25°C.
For complete details, see the EM1 or EM2 product pages.
PARAMETER | MIN. | TYP. | MAX. | UNITS | CONDITIONS |
---|
Supply Voltage | 4.5 | 5.0 | 5.5 | V |
|
---|
Supply Current |
| 27 | 33 | mA | CPR < 500, no load |
---|
| 54 | 62 | mA | CPR ≥ 500 and < 2000, no load |
| 72 | 85 | mA | CPR ≥ 2000, no load |
Low-level Output |
|
| 0.5 | V | IOL = 8mA max., CPR < 2000 |
---|
|
| 0.5 | V | IOL = 5mA max., CPR ≥ 2000 |
| 0.25 |
| V | no load, CPR ≥ 2000 |
High-level Output | 2.0 |
|
| V | IOH = -8mA max. and CPR < 2000 |
---|
2.0 |
|
| V | IOH = -5mA max. and CPR ≥ 2000 |
| 4.8 |
| V | no load and CPR < 2000 |
| 3.5 |
| V | no load and CPR ≥ 2000 |
Output Current Per Channel | -8 |
| 8 | mA | CPR < 2000 |
---|
-5 |
| 5 | mA | CPR ≥ 2000 |
Output Rise Time |
| 110 |
| nS | CPR < 2000 |
---|
| 50 |
| nS | CPR ≥ 2000, ± 5mA load |
Output Fall Time |
| 100 |
| nS | CPR < 2000 |
---|
| 50 |
| nS | CPR ≥ 2000, ± 5mA load |
PIN | DESCRIPTION |
---|
1 | Ground |
2 | Index |
3 | A Channel |
4 | +5 VDC Power |
5 | B Channel |
CYCLES PER SECOND |
0 to 300,000 |
CYCLES PER REVOLUTION (CPR) |
32 to 1,250 |
PULSES PER REVOLUTION (PPR) |
128 to 5,000 |
CYCLES PER REVOLUTION(CPR)
32 | 400 | 2048 |
50 | 500 | 2500 |
96 | 512 | 4000 |
100 | 540 | 4096 |
192 | 720 | 5000 |
200 | 900 |
|
250 | 1000 |
|
256 | 1024 |
|
360 | 1250 |
|
400 | 2000 |
|
Mechanical size
Downloads
If you need 3D drawings, please contact us directly.